Dc electric vehicle charging pile(IP54-20KW)

The EV charging pile series uses Voltronic's fully self-developed CCS controller and OCPP to ensure product stability and reduce maintenance risks. Patented ECO energy saving mode to reduce energy consumption. After the vehicle is charged, even if the charging gun is connected, the charging pile will enter the sleep mode (power consumption of 12W). If the charging gun is connected to another vehicle, the charging pile will resume charging. In addition, the patent modularizes the design of the charging module to facilitate replacement and reduce maintenance costs.

Product Features

  • Self-developed controller, CCS and OCPP charging module

  • Support a variety of charging standards :GB, CCS1, CCS2, CHAdeMO

  • TCharge up to 2 electric vehicles at the same time

  • Built-in RFID card reader

  • Support OCPP 1.6 JSON network and 3G/4G

  • APP Remote Firmware Upgrade (OTA)

  • Remote diagnostics simplify data collection and analysis

  • IP65 rating, IK10 destruction-proof case and IK8 touch screen

  • 7 Color touch LCD display, easy to configure

Application Field

  • Public places: Charging piles provide charging services for electric vehicles in public places such as parking lots, gas stations, airports, train stations, bus stops, etc. These places usually have a large flow of people and vehicles, and the charging demand of electric vehicles is correspondingly large, so the installation of charging piles in these places can provide convenient charging services for electric vehicles

  • Commercial areas: commercial areas such as shopping centers, supermarkets, restaurants, cafes, etc., are also important application scenarios for charging piles. These places usually have a large number of consumers and vehicles, and the installation of charging piles can not only provide charging services for electric vehicles, but also attract more consumers.

  • Residential areas: In residential areas, apartments, villas and other residential areas, charging piles provide charging services for residents. These places usually have residents' own electric vehicles, and the installation of charging piles can provide residents with convenient charging services and improve the quality of life of residents

  • In-transit charging scenario: Mainly applicable to highway long-distance charging, providing high-power DC piles and overcharged piles for fast charging during long-distance travel.

  • Solar energy storage: Lead-acid batteries can be used in the energy storage equipment of solar power generation systems to store the electricity generated in the process of solar power generation.

  • Fleet charging scenario: suitable for organizations or enterprises with multiple electric vehicles, with large charging coverage, mobile and other characteristics.


Product Selection

ModelAc inputRated DC output powerNet weight (kg)
IP65-20G32A.22KVA20KW44


















Technical Parameter

Model20kw
disposition
communicationDIN 70121,ISO/EC 15118 ed 1. CHAdeMO 1.2.GBT27930,GBT 34657
Codes and standardsIEC 61851-1 ed 3, IEC 61851-21-2 ed1,IEC 61851-23 ed 1,IEC 61851-24 ed1,
IEC 62196-2,IEC 62196-3. IEC 61000GBT18487.GBT20234
Universal characteristic
Weight (kg)44
Ac input power supply32 A, 22 kVA @ 400V 50Hz
Input voltage range400 VAC or 380 VAC +/10%
User interface
RFID readerSO/IEC14443 A/B Mifare RFlD reader
Language systemEnglish,Chinese,French,Spanish
Charging typeDC fast charging
Maximum currentCCS cable80A
Maximum currentCHAdeMO cable60A
Maximum currentGBT cable60A
Connector type3P+N+PE
Distribution systemTN-S.TN-C, TN-C-S, TT (required external RCD)
Socket systemC:CCS2 cable ,A: CCs1 cable,]: CHAdeMO cable .G: GBT cable
Overvoltage classType l
Cellular communicationGSM, 4G, LTE
Input frequency50 Hz or 60 Hz
Number of rechargeable electric vehicles
at the same time
Up to 2 (JC,JA models) Up to1 (C, A,J, G models)
Cable length5.0 m,Optional: 6.0 m/7.0 m
Electromagnetic compatibilityClass A (optional Class B) according to EN 61000-6-3:2007
ProtectionOvercurrent, overvoltage, undervoltage, integrated surge protection,
ground fault including Dcleakage protection,door opening protection
Electric energy measurementStandard: Meter for DC outlet, Optional: AC inlet
Dc output rated power (MAX)20KW
Dc output voltage200-1000 Vdc(Constant power from 300-1000Vdc)
Power factor≥0.98
THDi≤5%
efficiency≥93%
Standby power supply<35W
Short-circuit current10KA
Precharge current<1A
Inrush current<55A
Leakage current0.8mA
Universal characteristic
InstallWall-mount or pedestal stand
Working altitudeUp to 2000 m
humidness20-95 % Rh non-condensing
Class of protectionIP54 andlk10(cabinet)/lk8 (touchscreen)
Operating temperature-35 °C to +55°C
Housing materialSGCc, Optional: SUs430
Storage temperature-40°C to +70°C
Dimensions (L x W x H) mm200X450X600
User interface
User authenticationRFID, QR code
Emergency buttonYes
connectivityInternet access via 4G/3G/Ethernet(R]45)
User interface7" LCD high-contrast touchscreen
Communication protocolProprietary and OCPp 1.6]